Barry Pattern & Foundry

Standard Manhole Rings & Covers

H-20 Loading

H-20 Loading provides for:

  1. Two wheel loads of 9,000 lbs.
    +3,000 lbs. of impact per wheel or
  2. a single wheel load of 24,000 lbs.

H-20 products are designed for warehouse trucks, concrete mixers, and tractor trailers..

1,000 lb. loading

Light duty products are recommended for applications where maximum wheel loads do no exceed 1,000 pounds. In addition to areas with light traffic, these products are also excellent for pedestrian traffic.

Other loading options available upon request.

More Options

Manhole options available with all Barrycraft standard designs.

Strength: We offer light duty standard designs (1000 lb. loadings) to heavy duty designs (H-20). Other loadings are available upon request.

Cover designs: Each standard design can be solid, grated, vented or bolted and gasket sealed for water tight needs.

Custom made cover designs: Virtually any design is available upon request.

Lettering: We can letter the cover with virtually whatever you need at a low cost.

Locking devices: We offer outside hinge and hasp or a bolted cover.

Lifting devices: We offer the standard pickhole, steel lifting bar, steel drop through handle, cast in handle (for watertight manholes).

For Heavy Duty - Specify "H"

For Light Duty - Specify "L"

For H-20 Loading - Specify "H-20"

 

Base supported frame - Slab construction

 


 

B-1979 A
Manhole Riser

B-1979A

Take this Manhole Riser and simply "dop-on" the Riser to the existing frame and repace the lid. You have, with little labor and time consuming cost, raised the manhole the desired height in a matter of minutes. Each unit of cast iron is built to your own specifications. You do not have to disturb the existing manhole frame. Minimum riser height equals the cover thickness plus 1/2".

Specify:
"A" - The diameter of the existing manhole cover.
"B" - The thickness of the present manhole cover.
"C" - The height the manhole is to be raised.

 


 

Large Manhole Covers

B-1600 and B-1602 are our most popular manhole series, with standard seven inch deep frames.
B-1602 have light duty solid covers or grates.

Large Manhole Covers

Round B1600 Series - Bottom Flange
CAD Drawing Get DWG Viewer
H-20 Loading - For Heavy Loads
Table Dimensions in Inches
Manhole Style Cover Diameter
"A"
Cover Thickness
"B"
Clearing Opening
"C"
Ring
Overall
"E"
B-1600-A 20 1-3/4 18 30
B-1600-B 22 1-3/4 20 32
B-1600-C 24 1-3/4 22 34
B-1600-D 26 1-3/4 24 36
B-1600-E 29 1-3/4 27 39
B-1600-F 32 1-3/4 30 42
B-1600-G 38 1-3/4 36 48

Light Duty ring and cover or grate for slab construction.

Light Duty ring and cover or grate for slab construction. Excellent over pits and catch basins.

 

Round B6001 Series -Top Flange
CAD Drawing Get DWG Viewer
1,000 Lb. Loading - For Light Loads
Table Dimensions in Inches
Manhole Style Cover Diameter
"A"
Cover Thickness
"B"
Clearing Opening
"C"
Ring
Overall
"D"
Ring
Height
"E"
B-6001 6 3/4 5 10 4
B-6003 9 3/4 8 12 4
B-6005 12-3/4 3/4 11 14-3/4 4
B-6006 13 3/4 11-3/4 17 4
B-6007 14 3/4 12 20 4
B-6008 16 3/4 15 20-1/4 4
B-6009 18 3/4 16-1/2 21-1/4 4
B-6010 18 3/4 16-1/2 22-1/2 4
B-6011 18 3/4 17 22-1/2 4
B-6012 20-1/2 3/4 18 24 4
B-6020 21-1/2 3/4 20 27 4
B-6034 24 3/4 22 26-1/2 4
B-6040 24 3/4 22 30 4
B-6044 25 3/4 22 28 4
B-6044-A 26-1/2 3/4 25-1/2 30-1/2 4
B-6050 27 3/4 24 33-1/2 4
B-6070 27 3/4 25 31 4
B-6077 32 3/4 30 36-1/2 4
B-6077-A 32 3/4 30 36-1/2 4
B-6080 34 3/4 32 37 4
B-6090 37-1/2 3/4 36 42-1/2 4

 

B-1773

B-1773 Heavy Duty
Manhole Frame and Grate / Cover
Table Dimensions in Inches
Type No. A B C D E
B-1773 A 12 16 10 1 -1/4 2
B-1773 B 15 20 13 1 -1/4 2
B-1773 C 18 23 16 1 -1/4 2
B-1773 D 20 26 18 1 -1/4 2
B-1773 E 22 27 20 1 -1/4 2
B-1773 F 24 32 22 2 2 - 3/4
B-1773 G 26 34 24 2 2 - 3/4
B-1773 H 28 36 26 2 2 - 3/4
B-1773 I 30 28 38 2 2 - 3/4
B-1773 J 32 40 30 2 2 - 3/4
B-1773 K 34 42 32 2 2 - 3/4
B-1773 L 36 44 34 2 2 - 3/4
B-1773 M 38 46 36 2 2 - 3/4



B1792

CAD Drawing Get DWG Viewer

B-1792 has four inch deep frames. These are excellent in areas where deep paving is not required.
B-1793 series has light duty solid covers or grates.

 

Round B1792 Series - Bottom Flange
H-20 Loading - For Heavy Loads
Table Dimensions in Inches
Manhole Style
(Solid Lid)
Manhole Style
(Grate Lid)
Cover Diameter
"A"
Cover Edge
"B"
Clear
Opening
"C"
Base Opening
"D"
Ring
Overall
"E"
Ring Height
"F"
B-1792-AL B-1792-AG 10-1/4 1-1/2 8-1/2 10-1/2 14-1/2 4
B-1792-BL B-1792-BG 13-1/4 1-1/2 11-1/2 13-1/2 17-1/2 4
B-1792-CL B-1792-CG 16-1/4 1-1/2 14-1/2 16-1/2 20-1/2 4
B-1792-DL B-1792-DG 18-1/4 1-1/2 16-1/2 18-1/2 22-1/2 4
B-1792-EL B-1792-EG 22-1/4 1-1/2 20-1/2 22-1/2 26-1/2 4
B-1792-FL B-1792-FG 25-1/4 1-1/2 23-1/2 25-1/2 29-1/2 4
B-1792-GL B-1792-GG 28-1/4 1-1/2 26-1/2 28-1/2 32-1/2 4
B-1792-HL B-1792-HG 34-1/4 1-1/2 32-1/2 34-1/2 38-1/2 4
B-1792-JL B-1792-JG 40-1/4 1-1/2 38-1/2 40-1/2 44-1/2 4
B-1792-KL B-1792-KG 46-1/4 1-1/2 44-1/2 46-1/2 50-1/2 4

B-1794-A

B-1794-A

Manhole Frame, Solid Lid
Heavy Duty

(Power Company Standard)

 


 

B-1794-B

B-1794-B

Manhole Frame, Solid Lid
Heavy Duty

(Power Company Standard)

 


 

Angle Frames and Grated Covers

Angle Frames and Solid Cover
Dimensions in Inches
Catalog No. A B C
B-1809-A 21 3/4 19
B-1809-B 23-1/2 1-1/4 21-1/2
B-1809-C 24 3/4 22
B-1809-D 26 1 24
B-1809-E 29 2 27
B-1809-F 32 1 30
B-1809-G 34 2 32

 


 

B-1892

B-1892 top flange series are used in concrete slabs. Many styles also fit corrugated plastic or metal pipe.

CAD Drawing Get DWG Viewer

B-1893 series has light duty solid covers or grates.

Round B1892 & B1893 Series -Top Flange
H-20 Loading - For Heavy Loads
Table Dimensions in Inches
Manhole Style
"Solid Lid"
Manhole Style
"Grate Lid"
Cover Diameter
"A"
Cover Edge
"B"
Clear
Opening
"C"
Outside Dia-
meter
"DD"
Ring
Overall
"E"
Ring Height
"F"
B-1892-AL B-1892-AG 10-1/4 1-1/2 8-1/2 12 14-1/2 4
B-1892-BL B-1892-BG 13-1/4 1-1/2 11-1/2 15 17-1/2 4
B-1892-CL B-1892-CG 16-1/4 1-1/2 14-1/2 18 20-1/2 4
B-1892-DL B-1892-DG 18-1/4 1-1/2 16-1/2 20 22-1/2 4
B-1892-EL B-1892-EG 22-1/4 1-1/2 20-1/2 24 26-1/2 4
B-1892-FL B-1892-FG 25-1/4 1-1/2 23-1/2 27 29-1/2 4
B-1892-GL B-1892-GG 28-1/4 1-1/2 26-1/2 30 32-1/2 4
B-1892-HL B-1892-HG 34-1/4 1-1/2 32-1/2 36 38-1/2 4
B-1892-JL B-1892-JG 40-1/4 1-1/2 38-1/2 42 44-1/2 4
B-1892-KL B-1892-KG 46-1/4 1-1/2 44-1/2 48 50-1/2 4

 


 

Solid or Grated

Solid or Grated
Dimensions in Inches
Catalog No. A C E
B-1895-A1 10 x 10 8 x 8 11-1/4 x 11-1/4
B-1895-A2 12 x 12 10 x 10 13-1/4 x 13-1/4
B-1895-A3 14 x 14 12 x 12 15-1/4 x 15-1/4
B-1895-A4 18 x 18 16 x 16 19-1/2 x 19-1/2
B-1895-A5 20 x 20 18 x 18 21-1/2 x 21-1/2
B-1895-A6 22 x 22 20 x 20 23-1/2 x 23-1/2
B-1895-A7 24 x 24 22 x 22 25-1/2 x 25-1/2
B-1895-A8 26-1/4 x 26-1/4 24 x 24 27-1/8 x 27-1/8
B-1895-A9 28-1/2 x 28-1/2 26 x 26 30-1/4 x 30-1/4
B-1895-A10 32-3/8 x 32-3/8 30 x 30 33-1/2 x 33-1/2
B-1895-A11 36 x 36 34 x 34 38 x 38

Grated or Solid

Grated or Solid
Dimensions in Inches
Catalog No. A B C
B-1895-B1 10 x 20 8 x 18 11 x 21
B-1895-B2 12 x 24 10 x 22 13-1/4 x 25-1/4
B-1895-B3 14 x 28 12 x 26 15-1/4 x 29-1/4
B-1895-B4 18 x 36 16 x 34 19-1/2 x 37-1/2
B-1895-B5 18-1/4 x 50-1/4 16 x 48 19-1/4 x 51-1/4
B-1895-B6 20 x 40 18 x 38 21-1/2 x 41-1/2
B-1895-B7 23 x 29 20 x 26 24 x 30
B-1895-B8 24 x 48 22 x 46 25-1/2 x 49-1/2
B-1895-B9 24 x 54 22 x 52 28-1/2 x 55-1/2
B-1895-B10 24 x 60 22 x 58 31-1/2 x 61-1/2
B-1895-B11 24 x 72 22 x 70 38 x 74

 


 

B-1650

CAD Drawing Get DWG Viewer

Round B1650 Series - Top Flange
U.S. Government Standard Design
H-20 Loading - For Heavy Loads
Table Dimensions in Inches
Manhole Style Cover Diameter
"A"
Cover Thickness
"B"
Clearing Opening
"C"
Ring
Overall
"D"
Ring
Height
"E"
B-1650-A 21 2-1/2 18 27-1/2 5
B-1650-C 23 1-1/4 20 29-1/2 4
B-1650-D 27 1-1/4 24 33-1/2 4
B-1650-E 27 1-1/4 24 33-1/2 4
B-1650-F 27 2-1/2 24 33-1/2 5
B-1650-G 27 2-1/2 24 33-1/2 5
B-1650-H 29 1-3/4 27 35 6
B-1650-J 32-1/4 2 30 39-1/2 6

B-1654

B-1654

Alabama Department of Transportation
Cast Iron Manhole Cover
Type 190-S Ring and Cover
Barry B-1654 Vented Light Duty

 


 

B-1905

B-1905

 


Catch Basin Frames & Grates

B-1988-A

CAD Drawing Get DWG Viewer


Square B-1988A Series - Top Flange

H-20 Loading - For Heavy Loads

B-1989A Series has light duty solid covers or grates
Table Dimensions in Inches
Manhole Style
"Solid Lid"
Cover Dimensions "A" Cover Thick-
ness
"B"
Clear
Opening
"C"
Base
Opening
"D"
Frame Overall "E" Frame Depth
"F"
B-1988-A1 13-3/4 x 13-3/4 1-1/2 12 x 12 14 x 14 18 x 18 4
B-1988-A2 18 x 18 1-1/2 16 x 16 18-1/4 x 18-1/4 22 x 22 4
B-1988-A3 20 x 20 1-1/2 18 x 18 20-1/4 x 20-1/4 24 x 24 4
B-1988-A4 21-3/4 x 21-3/4 1-1/2 20 x 20 22 x 22 26 x 26 4
B-1988-A5 23-3/4 x 23-3/4 1-1/2 22 x 22 24 x 24 28 x 28 4
B-1988-A6 25-3/4 x 25-3/4 1-1/2 24 x 24 26 x 26 30 x 30 4
B-1988-A7 27-3/4 x 27-3/4 1-1/2 26 x 26 28 x 28 32 x 32 4
B-1988-A8 29-1/2 x 29-1/2 1-1/2 28 x 28 29-3/4 x 29-3/4 34 x 34 4
B-1988-A9 31-3/4 x 31-3/4 1-1/2 30 x 30 32 x 32 36 x 36 4
*B-1988-A10 37-3/4 x 37-3/4 1-1/2 36 x 36 38 x 38 42 x 42 4

* Cover furnished in 2 pieces

B-1988-B

CAD Drawing Get DWG Viewer

Rectangular B-1988B Series - Top Flange

H-20 Loading - For Heavy Loads

B-1989B Series has light duty solid covers or grates.

Table Dimensions in Inches
Manhole Style
"Solid Lid"
Cover Dimensions "A" Cover Thick-ness
"B"
Clear
Opening
"C"
Base Opening "D" Frame Overall "E" Frame Depth
"F"
B-1988-B1 14 x 20 1-1/2 12 x 18 14-1/4 x 20-1/4 18 x 24 4
B-1988-B2 13-1/2 x 25-1/2 1-1/2 12 x 24 13-3/4 x 25-3/4 18 x 30 4
B-1988-B3 19-1/2 x 25-1/2 1-1/2 18 x 24 19-3/4 x 25-3/4 24 x 30 4
B-1988-B4 19-1/2 x 31-1/2 1-1/2 18 x 30 20 x 32-3/4 24 x 36 4
B-1988-B5 19-3/4 x 37-3/4 1-1/2 18 x 36 20 x 38 24 x 42 4
B-1988-B6 25-1/2 x 31-1/2 1-1/2 24 x 30 25-3/4 x 31-3/4 30 x 36 4
B-1988-B7 25-3/4 x 37-3/4 1-1/2 24 x 36 26 x 38 30 x 42 4
*B-1988-B8 25-3/4 x 49-3/4 1-1/2 24 x 48 26 x 50 30 x 54 4
*B-1988-B9 31-3/4 x 37-3/4 1-1/2 30 x 36 32 x 38 36 x 42 4
*B-1988-B10 31-1/2 x 49-1/2 1-1/2 30 x 48 31-3/4 x 49-3/4 36 x 54 4

* Cover furnished in 2 pieces

B-1878-A

CAD Drawing Get DWG Viewer

Square B-1878A Series - Bottom Flange

H-20 Loading - For Heavy Loads

B-1879A Series has light duty solid covers or grates

Table Dimensions in Inches
Manhole Style
"Solid Lid"
Cover Dimensions "A" Cover Thick-
ness
"B"
Clear
Opening
"C"
Base
Opening
"D"
Frame Overall
"E"
Frame Depth
"F"
B-1878-A1 13-3/4 x 13-3/4 1-1/2 12 x 12 14 x 14 18 x 18 4
B-1878-A2 18 x 18 1-1/2 16 x 16 18-1/4 x 18-1/4 22 x 22 4
B-1878-A3 20 x 20 1-1/2 18 x 18 20-1/4 x 20-1/4 24 x 24 4
B-1878-A4 21-3/4 x 21-3/4 1-1/2 20 x 20 22 x 22 26 x 26 4
B-1878-A5 23-3/4 x 23-3/4 1-1/2 22 x 22 24 x 24 28 x 28 4
B-1878-A6 25-3/4 x 25-3/4 1-1/2 24 x 24 26 x 26 30 x 30 4
B-1878-A7 27-3/4 x 27-3/4 1-1/2 26 x 26 28 x 28 32 x 32 4
*B-1878-A8 29-1/2 x 29-1/2 1-1/2 28 x 28 29-3/4 x 29-3/4 34 x 34 4
*B-1878-A9 31-3/4 x 31-3/4 1-1/2 30 x 30 32 x 32 36 x 36 4
*B-1878-A10 37-3/4 x 37-3/4 1-1/2 36 x 36 38 x 38 42 x 42 4

* Cover furnished in 2 pieces

B-1878-B

Rectangular B1878B Series - Bottom Flange

H-20 Loading - For Heavy Loads

B-1879B Series has light duty solid covers or grates.

Table Dimensions in Inches
Manhole Style
"Solid Lid"
Cover Dimensions "A" Cover Thick-ness
"B"
Clear
Opening
"C"
Base Opening "D" Frame Overall "E" Frame Depth
"F"
B-1878-B1 14 x 20 1-1/2 12 x 18 14-1/4 x 20-1/4 18 x 24 4
B-1878-B2 13-1/2 x 25-1/2 1-1/2 12 x 24 13-3/4 x 25-3/4 18 x 30 4
B-1878-B3 19-1/2 x 25-1/2 1-1/2 18 x 24 19-3/4 x 25-3/4 24 x 30 4
B-1878-B4 19-1/2 x 31-1/2 1-1/2 18 x 30 20 x 32 24 x 36 4
B-1878-B5 19-3/4 x 37-3/4 1-1/2 18 x 36 20 x 38 24 x 42 4
B-1878-B6 25-1/2 x 31-1/2 1-1/2 24 x 30 25-3/4 x 31-3/4 30 x 36 4
B-1878-B7 25-3/4 x 37-3/4 1-1/2 24 x 36 26 x 38 30 x 42 4
*B-1878-B8 25-3/4 x 49-3/4 1-1/2 24 x 48 26 x 50 30 x 54 4
*B-1878-B9 31-3/4 x 37-3/4 1-1/2 30 x 36 32 x 38 36 x 42 4
*B-1878-B10 31-1/2 x 49-1/2 1-1/2 30 x 48 31-3/4 x 49-3/4 36 x 54 4

* Cover furnished in 2 pieces

 

Catch Basin Frames & Grates

Heavy duty and light duty rectangular frame and cover or grate for built up construction. Most popular as a catch basin.

Catch Basin Frames & Grates

 


Round - U.S. Government, Bell Telephone & Power Company Design

Barrycraft's B-1640 meets the U.S. Government's standard designs. Barrycraft's B-1640 U.S. Government series in addition meets the Bell Telephone and Power Company's designs. These designs will support an H-20 loading.

B1640

CAD Drawing Get DWG Viewer

B1640 Series - Bottom Flange
U.S. Government, Bell Telephone & Power Company Design
H-20 Loading - For Heavy Loads
Table Dimensions in Inches
Manhole Style
Cover Dimensions "A" Cover Thickness "B" Clearing
Opening
"C"
Base Opening "D" Ring Overall "E" Ring Height "F"
B-1640-A 26 1-3/8 24 35 43 10
B-1640-B 29 1-3/8 27 38 46 10
B-1640-B1 29 1-3/8 27 34 46 5-5/8
B-1640-C 32 1-3/8 30 41 49 10
B-1640-C1 32 1-3/8 30 37 49 5-5/8
B-1640-D 38 1-1/2 36 40 50 10

 


 

Angle Frames and Grated Covers

Angle Frames and Grated Covers
Dimensions in Inches
Catalog No. A B C
B-2596-A 21 3/4 19
B-2596-B 23-1/2 1-1/4 21-1/2
B-2596-C 24 3/4 22
B-2596-D 26 1 24
B-2596-E 29 2 27
B-2596-F 32 1 30
B-2596-G 34 2 32

 


 

B-4042

A = Pipe Size minus 1/4" Diameter
(click on image to enlarge)

CAD Drawing Get DWG Viewer

B-4042 - Heavy Duty Grates For The End Of Corrugated Pipe Or PVC Pipe
Pipe Size A Overall Diameter (B) Edge (C) Center (D)
6 5-3/4 7-5/8 1/2 5/8
8 7-3/4 10 9/16 1-1/8
10 9-3/4 12 3/4 1-1/4
12 11-3/4 14-1/2 3/4 1-1/4
15 14-3/4 17-1/2 3/4 1-1/2
18 17-3/4 20-1/2 3/4 1-7/8
24 23-3/4 26-3/8 3/4 2-3/4
30 29-3/4 32-1/2 1 2-3/4
36 35-3/4 38-1/2 1-1/8 3
42 41-3/4 44-1/2 1-1/2 4
48 47-3/4 50-1/2 1-1/2 4-1/4

 


B-6461

B-6461 Heavy Duty
Pressure Type Manhole Frame and Cover - Water Tight
Table Dimensions in Inches
Type No. A B C D E F No. of Bolts
B-6461 AH 10-1/4 1-1/2 8-1/2 10-1/2 14-1/2 4 4
B-6461 BH 13-1/4 1-1/2 11-1/2 13-1/2 17-1/2 4 4
B-6461 CH 16-1/4 1-1/2 14-1/2 16-1/2 20-1/2 4 6
B-6461 DH 18-1/4 1-1/2 16-1/2 18-1/2 22-1/2 4 6
B-6461 EH 22-1/4 1-1/2 20-1/2 22-1/2 26-1/2 4 6
B-6461 FH 25-1/4 1-1/2 23-1/2 25-1/2 29-1/2 4 6
B-6461 GH 28-1/4 1-1/2 26-1/2 28-1/2 34-1/2 4 6
B-6461 HH 34-1/4 1-1/2 32-1/2 34-1/2 38-1/2 4 8
B-6461 JH 40-1/4 1-1/2 38-1/2 40-1/2 44-1/2 4 10
B-6461 KH 46-1/4 1-1/2 44-1/2 46-1/2 50-1/2 4 10

B-6462

B-6462 Heavy Duty
Pressure Type Manhole Frame and Cover - Water Tight
Table Dimensions in Inches
Type No. A B C D E F No. of Bolts
B-6462 AH 10-1/4 1-1/2 8-1/2 10-1/2 14-1/2 4 4
B-6462 BH 13-1/4 1-1/2 11-1/2 13-1/2 17-1/2 4 4
B-6462 CH 16-1/4 1-1/2 14-1/2 16-1/2 20-1/2 4 6
B-6462 DH 18-1/4 1-1/2 16-1/2 18-1/2 22-1/2 4 6
B-6462 EH 22-1/4 1-1/2 20-1/2 22-1/2 26-1/2 4 6
B-6462 FH 25-1/4 1-1/2 23-1/2 25-1/2 29-1/2 4 6
B-6462 GH 28-1/4 1-1/2 26-1/2 28-1/2 32-1/2 4 6
B-6462 HH 34-1/4 1-1/2 32-1/2 34-1/2 38-1/2 4 8
B-6462JH 40-1/4 1-1/2 38-1/2 40-1/2 44-1/2 4 10
B-6462 KH 46-1/4 1-1/2 44-1/2 46-1/2 50-1/2 4 10

 

 


B-3485-A

CAD Drawing
Get DWG Viewer

Airport Drainage Inlet
Frames and Grates

B-3485-A
B-3485-B - 2 Grate Unit
B-3485-C - 3 Grate Unit
B-3485-D - 4 Grate Unit

B-3485-B, C and D grates are furnished as ductile iron

Grates can be furnished bolted with counter sunk hex head bolts

 


 

B-3486

B-3486

Extra Heavy Duty Airport Inlet

 


 

B-3490

B-3490

Airport Drainage Frame
and Double Grate

 

 


B-3492-A

CAD Drawing Get DWG Viewer

Airport Servicing Areas
Drainage

B-3492-A

The frame can be furnished with anchor bolt holes
The grates can be furnished bolted with counter sunk hex head bolts
4-1/2" x 2-1/2" hex head bolts per grate (recessed)

Loadings shown are for gray and ductile cast iron. For aluminum covers and grates: If H-20 loading is required - it must be specified.

 


 

Locking Devices
A1 A3
A2 A4
Lifting Devices
LD1
LD4
LD2 LD5
LD3 LD6